Call (000) 000-0000

GE Refrigerator Error Codes

What GE refrigerator error codes mean and what a technician checks for each one. Need it fixed? GE refrigerator repair in Charlotte.

Dispenser-display refrigerators (owner codes)

CodeMeaningWhat to check
FFFreezer temperature too high (frozen food may thaw)Doors close, gaskets; press System Check; if PF also shown - outage caused it. Service: fans, defrost, sealed system.
PFPower was interruptedCheck cord/outlet, check food, press System Check.
CIIce maker not operating properlyClear jammed ice, restore water; if returns - ice maker assembly / harness.
DEDemo mode ON (cooling off)Unplug 1-2 min; if still DE contact GE.
dEDefrost system not run properly (24-48 h)Defrost heater, defrost thermistor/thermostat, harness. Normal if room <55°F.
CCSet temperature incorrect / freezer too warm >2 hAdjust controls, close doors, gaskets.
tCTurboCool active (not an error)None.
tFTurboFreeze active (not an error; may look like 'EF')None.

French-door / bottom-freezer service mode (GFE/GNE/GYE/PFE/PYE/CFE/CYE/CWE/PWE/ZWE)

CodeMeaningWhat to check
0001FF (fresh food) thermistor reading out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0003FZ (freezer) thermistor reading out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0004FZ evaporator thermistor reading out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0005Electronic deli pan thermistor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0006FF evaporator thermistor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0008Ambient temperature thermistor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0009Ambient humidity sensor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0010FZ icemaker thermistor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0100FZ fan feedback missing when runningService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0101FZ fan feedback present when offService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0102FZ fan cannot reach target speedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0103Condenser fan feedback missing when runningService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0104Condenser fan feedback present when offService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0105Condenser fan cannot reach target speedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0106FF fan feedback missing when runningService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0107FF fan feedback present when offService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0108FF fan cannot reach target speedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0109Ice box fan feedback missingService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0110Ice box fan feedback present when offService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0111Ice box fan cannot reach target speedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0112Deli pan fan feedback missingService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0113Deli pan fan feedback present when offService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0114Deli pan fan cannot reach target speedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0200FZ defrost heater timed out (check 0004)Service mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0201FF defrost heater timed out (check 0006)Service mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
02025 consecutive FZ extended defrostsService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
02035 consecutive FF extended defrostsService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0301Temp satisfied >3 h with no compressor runService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0303FF temperature exceeds 55°FService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0304FZ temperature exceeds 25°FService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0403Main board software faultService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0500Cannot reach target hot water temperatureService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0501Flow meter: no signal during dispenseService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0502Flow meter signal with no dispensingService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0503Paddle switch pressed >7 minService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0504Hot water tank not full while heatingService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0511FF ice maker thermistor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0512Ice box thermistor out of rangeService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0515 / 0517Door board hardware faultService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0523Feature board communication errorService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0525Brew (K-cup) module not detectedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0601FF IM harvest extended >10 minService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0603FF IM harvest not completed after 30 minService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0604FF IM no water supply detectedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0605FF IM senses bucket full after dispenseService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0606FF IM mold heater not heatingService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0651FZ IM harvest extended >10 minService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0654FZ IM no water supply detectedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0655FZ IM mold heater not heatingService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0700Stuck keys on dispenser boardService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0713FF door open 15 min continuouslyService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0717FZ door open 15 min continuouslyService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0721Upper AutoFill sensor error (clean sensors)Service mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0722Display board errorService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0800RFID board hardware failure (check filter)Service mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0802RFID not detecting filter tagService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.
0803RFID filter authentication failedService mode: read/clear codes (test 0000 show, 0001 clear). Check the named sensor/fan/heater and its harness.

GE appliance down?